653 research outputs found

    Intimai flap prolapse in aortic dissection

    Get PDF

    Recent Developments in Federal Income Taxation

    Full text link

    Charged Particle Distributions and Heat Transfer in a Discharge Between Geometrically Dissimilar Electrodes: From Breakdown to Steady State

    Get PDF
    The low-current electric discharge from a fine wire anode to a planar cathode in atmospheric pressure air is numerically simulated from high-voltage prebreakdown through electron temperature growth, then ionization and consequent current growth to steady state, limited by a ballast resistor in the external circuit. Conservation of number ~mass! for ions and electrons, Gauss’ law for the self-consistent electric field, and energy conservation for electrons have been solved from breakdown to steady state in a body fitted coordinate system generated specifically for these two geometrically dissimilar electrodes. To facilitate the discussion of the results, the discharge has been categorized under ~a! electron acceleration period, ~b! charged particle generation period, ~c! current increase and voltage drop period, and ~d! current and voltage stabilization period. Results are given for transient electron, ion, and temperature distributions in the gap as well as current growth and voltage drop across the gap. Heat flux from the discharge to the wire is calculated. The numerical simulations were compared with experiments performed under the same conditions on a wire bonding machine with very close correspondence

    Effect of Negative Ions on Electrical Breakdown in a Nonuniform Air Gap Between a Wire and a Plane

    Get PDF
    Electrical breakdown of an axisymmetric, atmospheric pressure air gap between a wire and a plane has been investigated for a gap length of 0.5 mm. 0- and 02- have been identified as the negative ions affecting the discharge development in air, besides electrons and positive ions, and have been included in the electrical breakdown model. Five coupled two-dimensional transient partial differential equations describing the discharge evolution in the air gap have been solved using a finite difference algorithm developed earlier. Temporal development of the charged particle number densities, electrostatic potential, electric field, and current at both the electrodes is presented when the wire is negatively biased at 2500 V. The impact of negative ions on gap breakdown has been assessed by comparing the results of analyses with and without negative ions. It is concluded that the negative ions have negligible effect during the early stages of the discharge development. However, as the discharge evolves, the negative ions cause a net loss of electrons from the discharge. The effect is most pronounced away from the discharge axis, where peaks in the electron density occur as breakdown proceeds. Radial spread of discharge and current growth rate are relatively unaffected by the presence of negative ions, but the magnitude of total current at the electrodes has been found to decrease by a decade when the negative ions are present

    Two-Dimenslonal Analysis of Electrical Breakdown in a Nonuniform Gap Between a Wire and a Plane

    Get PDF
    Electrical breakdown of a gap between a wire (modeled as a hyperboloid) and a plane has been investigated numerically by solving the two-dimensional form of the diffusion flux equations for the charged particle number densities and Poisson\u27s equation for the self-consistent electric field. Electron impact ionization, thermal ionization, and three-body recombination have been considered as the charged particle production and loss mechanisms. The electrode surfaces are considered to be absorbing and the initial density of the particles is small, but nonzero, A gap length of 0.5 mm is investigated and the gas medium is air or argon at atmospheric pressure. The temporal development of the profiles of ion and electron number densities, potential and electric field, and current growth on both the electrodes are presented when the applied voltage is 1500 and 2500 V for both positive and negative wires. When the wire is negatively biased, the peaks in the radial distribution of both of the charged particle densities near the wire occur off the axis except during the very early part of the breakdown. With positive polarity, the electron density maximum always occurs on the discharge axis, while for ions it moves away from the axis, later in the transient, due to the reverse particle drift in the electric field from the negative polarity case, The discharge spreads farther out into the ambient (almost two times the gap length) when the wire is negatively biased than with positive polarity. The effect of charge separation on the externally applied electric field is significant at voltages 2500 V and higher. Ionization is greater in argon than in air for a fixed potential difference between the electrodes

    Predictive value of grade point average (GPA), Medical College Admission Test (MCAT), internal examinations (Block) and National Board of Medical Examiners (NBME) scores on Medical Council of Canada qualifying examination part I (MCCQE-1) scores

    Get PDF
    Background: To determine whether the pre-medical Grade Point Average (GPA), Medical College Admission Test (MCAT), Internal examinations (Block) and National Board of Medical Examiners (NBME) scores are correlated with and predict the Medical Council of Canada Qualifying Examination Part I (MCCQE-1) scores.Methods: Data from 392 admitted students in the graduating classes of 2010-2013 at University of Manitoba (UofM), College of Medicine was considered. Pearson’s correlation to assess the strength of the relationship, multiple linear regression to estimate MCCQE-1 score and stepwise linear regression to investigate the amount of variance were employed.Results: Complete data from 367 (94%) students were studied. The MCCQE-1 had a moderate-to-large positive correlation with NBME scores and Block scores but a low correlation with GPA and MCAT scores. The multiple linear regression model gives a good estimate of the MCCQE-1 (R2 =0.604). Stepwise regression analysis demonstrated that 59.2% of the variation in the MCCQE-1 was accounted for by the NBME, but only 1.9% by the Block exams, and negligible variation came from the GPA and the MCAT.Conclusions: Amongst all the examinations used at UofM, the NBME is most closely correlated with MCCQE-1

    Electrode Heating in a Wire-to-Plane Arc

    Get PDF
    A steady wire-to-plane electric discharge has been modeled in a prolate spheroidal coordinate system with the wire shape taken as a hyperboloid of revolution. A set of continuum conservation equations for the charged particle densities and temperatures together with Poisson’s equation for the self-consistent electric potential describe the steady electric discharge process. These equations have been solved numerically to obtain ion and electron densities, temperature distribution, and electrode heat fluxes. Particle densities show the main body of the arc is quasineutral bounded by space charge sheaths at both electrodes. The temperature is greatest in a region around the discharge axis about one-third of the distance from the wire to the plane. Strong electric fields are concentrated in the electrode sheaths. The heat flux to the wire is sharply peaked near the tip but on the plane it decays slowly away from the discharge axis. The knowledge of heat transfer from the arc to the electrodes is useful in determining arc parameters that govern the ball formation process used in wire bonding of microelectronic semiconductor chips as well as welding processes

    Oscillatory enhancement of the squeezing flow of yield stress fluids: A novel experimental result

    Get PDF
    The extrusion of a yield stress fluid from the space between two parallel plates is investigated experimentally. Oscillating the magnitude of the squeezing force about a mean value (F = f[1+αcos(ωt)]) was observed to significantly enhance the flow rate of yield stress fluids, while having no effect on the flow rate of Newtonian fluids. This is a novel result. The enhancement depends on the magnitude of the force, the oscillatory frequency and amplitude, the fluid being squeezed, and the thickness of the fluid layer. Non-dimensional results for the various flow quantities have been presented by using the flow predicted for the constant-force squeezing of a Herschel-Bulkley yield stress fluid as the reference. In the limit of constant-force squeezing, the present experimental results compare very well with those of our earlier theoretical model for this situation (Zwick, Ayyaswamy & Cohen 1996). The results presented in this paper have significance, among many applications, for injection moulding, in the adhesive bonding of microelectronic chips, and in surgical procedures employed in health care
    • …
    corecore